air conditioner has a water leaking? Master something without too much effort! How to deal with it simply
Now, whether in public or at home, we often come into contact with air conditioning. It is necessary to understand some common sense. Proper installation of air conditioner can effectively prevent water leakage of indoor unit of air conditioner.
Generally, the leakage of air conditioner is mostly due to the installation problem, not the quality of air conditioner. So how to deal with the leakage of air conditioner?
Causes and solutions of water leakage of indoor unit of air conditioner:
1. The installation of wall mounted internal machine is not horizontal. The common reason is that the internal machine is low on the left and high on the right.
Solution: readjust the angle of fixed wall panel horizontally.
2. The connecting pipe of wall mounted indoor unit is lower inside and higher outside the wall hole.
Solution: re punch (or ream) and adjust the angle of through wall hole to achieve inner high and outer low.
3. The position of the water outlet of the wall mounted indoor unit is lower than the position of the through wall hole, so that the condensate cannot flow out.
Solution: increase the height of wall panel.
4. Problem: too much ash is accumulated in the condensate tray and the drain hole is blocked.
Solution: clear the water tray to make the drainage hole unobstructed.
5. Problem: the condensate drain pipe is bent or flattened.
Solution: check the drain pipe and replace it with a new one if it is damaged.
People should be very familiar with air conditioners. There are many different types and models of air conditioners, but if the air conditioner leaks, the basic reasons are the same, and the treatment methods for air conditioner leaks are the same.
When the air conditioner leaks, we should cut off the power supply in time, and then conduct inspection and maintenance, or find after-sales personnel for door-to-door maintenance.
The leakage of air conditioner depends on what causes it. If it is because the indoor unit is low on the left and high on the right during installation.
Then it is necessary to adjust the position of the indoor unit. If the drain of the air conditioner is lower than the position of the through wall hole, the condensate generated by the air conditioner cannot flow out normally. In this case, it is necessary to raise the height of the wall panel.